Configuring Regional Parameters and Supplementary Services
Scripting for Cadences, Call Progress Tones, and Ring Tones
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide
•
Number of Cadence Sections = 1
•
Cadence Section 1: Section Length = 10 s
•
Number of Segments = 1
•
Segment 1: On=forever, with Frequencies 1 and 2
•
Total Tone Length = 10s
•
Example 2: Stutter Tone
•
350@-19,440@-19;2(. 1 /. 1 /1+2);10(*/0/1+2)
•
Number of Frequencies = 2
•
Frequency 1 = 350 Hz at –19 dBm
•
Frequency 2 = 440 Hz at –19 dBm
•
Number of Cadence Sections = 2
•
Cadence Section 1: Section Length = 2s
•
Number of Segments = 1
•
Segment 1: On=0. 1 s, Off=0. 1 s with Frequencies 1 and 2
•
Cadence Section 2: Section Length = 10s
•
Number of Segments = 1
•
Segment 1: On=forever, with Frequencies 1 and 2
•
Total Tone Length = 12s
Example: SIT Tone
985@-16,1428@-16,1777@-16;20(.380/0/1,.380/0/2,.380/0/3,0/4/
0)
•
Number of Frequencies = 3
•
Frequency 1 = 985 Hz at –16 dBm
•
Frequency 2 = 1428 Hz at –16 dBm
•
Frequency 3 = 1777 Hz at –16 dBm
•
Number of Cadence Sections = 1
•
Cadence Section 1: Section Length = 20s
7