Appendix

This product is compliant with ULC 60839 -11-1 Grade 1. Below tables lists the evaluated
mandatory requirements.
Table 7-1
Access Point Interface requirements
When the release time is system-defined, the permitted value shall not be
less than 3 s
Provide access control for entry into a protected (controlled) area
Access granted conditional upon credential validity (blocked, suspended,
invalid)
Table 7-2
Table 3 –Indication and annunciation requirements
Visual and/or audible indication required
when access is granted
Table 7-3
Access levels
The minimum ratio between number of possible user codes and number of
allocated codes shall be at least 1 000 to 1 when system is using recognition
of a valid user by memorized information only e.g.: up to 10 users – 4 digits, up
to 100 users – 5 digits, up to 1 000 users – 6 digits, etc
In normal mode of operation the system shall use complete token information
(facility code and card number, or unique card number) for recognition
Tokens with coding system structure visible to unaided human eye shall not
be used
The token identity number readable on the token not to be a direct
representation of the entire coding
Optional ULC 60839-11-1 requirements has not been evaluated by UL.
Note
Yes/No
Yes
Yes
Yes
Display/Alert/Loggin
Yes/No
g/Indication
Indication
Yes
Yes/No
Yes
Yes
Yes
Yes
Document 800-26311_ A - February 2020
| 121
7
Grade 1 OP/M
M
M
M
Grade 1 OP/M
M
Grade
M
M
M
M