(4) Power source
® The power supply line should have a capacity of more
than 15A, capable of supplying more than 90% of the
rated voltage at full load.
@
Do
not use an extension
cord or operate any other
equipment from the same wall outlet.
(5) Ground connection
®D Use
a properly
grounded
(three
prong) wall outlet
only.
@® Wall outlet must be properly grounded.
©) Connect the ground cable to an authorized ground line
connected
to 3 copper bar more than 65cm
(25.6")
buried underground, but never connect it to a gas line.
(1) Cleaning the corona wire
(@ Unlock the developing unit access cover lock lever, and
remove the developing unit.
2) Open the clam shell.
@) Remove the drum holder unit from the copier.
Main corona unit
Remove the green screw.
Drum holder unit
@® Remove the transfer corona unit.
Transfer corona unit
SF-7200
@) Remove the discharge corona unit.
NOTE:
Use Caution to avoid drum damage.
Drum holder unit
743
emove the
green screw.
(2) Installing the drum and the cleaner blade
(2) Open the clam shell.
Drum holder unit
(4) Remove the cleaner blade tension screw to release the
cleaner
blade
tension
and
remove
the
blade cover.
(2 screw)
Raat