Used to cancel the status code U1.
pow
| Used to cancel the status code other than U1, U2 and CH.
20
Used to check the maintenance preset counter contents. Set to 15000 with the SF-7200, and its
contents will be displayed on the multicopy window in three cycles to indicate a whole number, two
digits at a time.
:
Cor] > [eae] > [ae] + [Bank] + [oo] + Ceengbiene}
Used to check the machine's total copy count. Will be displayed in the same manner as (16) above.
Actual copy count in the maintenance counter is displayed. Will be displayed in the same manner as
(16) above.
Used to reset the maintenance counter to zero after the completion of machine maintenance. This
test command must be executed after completion of machine maintenance.
1. Used to check the warmup time.
2. Used to perform the aging test according to the entered copy number. When the test command is
executed, the machine goes into the ordinary machine operating mode, and the warmup time
starts to count from 0 and increases every 2 seconds. The warmup time is indicated on the multi-
copy window. When the RPL turns on, warmup counting is stopped and the display remains as
it is. Depression of the CLEAR key, entry of a copy number, and depression of the REPEAT key
followed by the PSW begins the aging operation until the entered copy number is reached. The
paper misfeed detect functions stays active.
The aging test is carried out without using paper. The paper misfeed sensor is disabled.
Though identical to the test command 21, the warmup time is omitted and the heater throuble
detect function and paper misfeed detect function is disabled. The heater lamp does not actuate.)
24
5
Permits machine operational checks by omitting warmup time. RPL lights up immediately after the
execution of the test command. Though it is possible to immediately proceed to check machine
operations, status code H4 may appear when operating at a low temperature.
2
1. Used to adjust the developer level (toner level).
2. Used to check action of rotating parts. With this test command, the main motor runs for 1
minute while applying the developing bias. The TPL will turn on if the toner level is too low.
3. Used to check the developing bias voltage.
>
Black developer
j
j
Red developer
Sm
pe"
© | SDE
Blue developer
:
Brown developer
'e
The lens moves from normal > x 0.8 > x 0.7 > x 2.0 > x 1.22 > normal (AB series). Lens moves
from normal > x 0.75 > x .064 > x 2.0 > x 1.22 > normal {inch series). The lens stops for 2
seconds at each position. Used to check dark box operations.