@) V-ring insertion
Pay attention
to the direction
of the V-ring. There
should be no clearance between the V-ring and the MG
roller shaft.
MG roller
V-ring
V-ring
3. Clearance Adjustment between the Doctor Blade
and the MG Roller
The clearance
between
the MG roller sleeve and the DV
doctor blade should be adjusted to 2.0+0.05mm. Move the
DV doctor blade in the arrow direction to adjust.
Use the DV clearance gauge UKOG-0112FCZZ.
2.0£0.05mm
MG roller
Doctor blade
'
adjusting screw
DV doctor
Doctor adjusting plate
oe
SY
securing screw
rae
Main pole
25.5+0.2mm
4. Main Pole Adjustment
.
Load the developing unit with developer, and wipe a finger
gently across the MG
roller surface.
A dark band about
10mm wide will appear to indicate the location of the main
pole inside the MG roller. Adjust the center of the dark
band to 25.5+0.2mm
from the base of the doctor blade
with the MG adjusting screw.
adjusting
plate
i
MG adjusting plate
MG adjusting plate
securing screw
5. DV Connector Wiring
The developing unit connector wiring differs depending on
the kind of developer used.
The gray wire from the #2-pin of the connector must be
connected
to one
of #5-pin to #8-pin of the connector
according to the developer kind. (See the figure below.)
Gray wire
#2-pin to #5-pin (TSW1): Black developing unit
#2-pin to #6-pin (TSW2): Red developing unit
#2-pin to #7-pin (TSW3): Blue developing unit
#2-pin to #8-pin (TSW4): Brown developing unit
As the #2-pin of the service parts developing
unit is left
unconnected, it must be connected according to the devel-
oper color used.