6) Transfer corona output adjustments.
a. Enter
the
test
command
10. The
transfer
high
voltage unit will activate for 30 seconds.
b. Measure the output current.
The output current for the transfer corona should
be: 20.0£2.QuA.
Adjust the pot on the rear frame side if necessary.
THVG output
adjusting pot
THVG
c. Discharge corona current adjustment
® Observe the procedures (3)-a-Dthrough®.
(DCD sheet
installation)
OQ) Clean
the
discharge
corona
wire,
and
replace
the
discharge corona unit back in the machine. Do not set
the main and transfer corona units and the developing
unit back in the machine.
8) Close frames.
@ Connect the DCD
test leads to the digital multimeter
(or ammeter) and the DCD test sheet.
Green clip
n>
Orange
<2
DS
Yellow clip
Microswitch
we
Black
Unpainted
—'4
chassis
Black clip
ground
Electrode harness
Digital multimeter (UKOGE0019FCZ2Z)
IMPORTANT:
Make sure that the black test lead is connected to a
good chassis ground.
When
the digital multimeter
is used, connect the
SF-7200
test leads as follows:
Blue clip to the negative jack of the meter.
Red clip to the positive jack of the meter.
And set the meter range as follows:
Knob-1 to DCmA range.
Knob-2 to 0.2.
When the ammeter is used, connect the test leads as
follows:
Blue clip to the negative jack of the ammeter.
Red clip to the positive jack of the ammeter.
IMPORTANT:
Make sure that the black test lead is connected to a
good chassis ground.
There
may
be
slight
fluctuations
in the
meter
reading during this measurement.
The average value
is used as the measured value.
() Measure the drum current at the front and rear frame
sides.
The output current for the discharge corona should be:
4.0+1.0uA.
a. Enter
the test command
11.
The
discharge
will
activate for 30 seconds.
@ When
the test harness
microswitch
is off, the
front
frame
side current
is indicated
on
the
meter.
@
When the test harness microswitch is on, the rear
frame
side
drum
current
is indicated
on
the
meter.
(OFF)
(ON)
'ee ee
N/O COM|
«———
N/O
COM
@
lf the current difference is greater than 1.0uA,
replace the corona unit.
©) Discharge corona output adjustments.
a. Enter
the
test command
11. The
discharge
high
voltage unit will activate for 30 seconds.
b. Measure the output current.
The output current for the discharge corona should
be: 4.0£1.QuA.
Adjust the pot on the rear frame side if necessary.
DHVG output adjusting pot
MHVG/DHVG