[10] Fusing unit
_
. General Description
®
A teflon roller is used for the upper heat roller and a
silicon roller is used for the lower heat roller.
®
The cleaning roller is impregnated
with
silicon oil to
increase the cleaning effect of the heat rollers. The upper
cleaning roller cleans the area where the thermistor is in
contact.
®
Three separator pawls are used for the upper heat roller.
@® The
upper
heat
roller surface
temperature
is set to
180°C and drops to 120°C in power standby.
2. Major Parts Replacement
(1) How to install the cleaning roller
Lower cleaning roller
DC power
supply PWB
SF-7200
AC power
Triac
Copy lamp
Heat roller
Paper
Thermistor
1) Remove
the two screws that secure the paper exit
guide.
(Front frame side)
Remove the paper exit guide securing screw.
@) Open the fusing unit.
8 Pivot the paper exit guide to the paper exit side.
10—1