Download Print this page

Sharp SF-7200 Service Manual page 69

Advertisement

14
14-6
(AB series) normal > x 0.8 > x 0.7 > x 2.0 > x 1.22 Lens steps through the ratios continuously
(aging).
(Inch series) Lens is moved from normal > x 0.75 > x 0.64 > x 2.0 > x 1.22 Lens steps through the
ratios continuously.
Lens stop 2 seconds at each point. Used to check dark box operations.
Displays the contents of the developer preset counter, in a similar manner as test command 16. Also, .
the kind of developer in use can be monitored on the display, in a similar manner as test command 25.
Displays the contents of the copy number preset counter, in a similar manner as test command
16.
Also, the kind of developer in use can be monitored on the display, in a similar manner as test
command 25.
Resets the contents of the copy number counter, in a similar manner at test command 16.
Also, the kind of developer in use can be monitored on the display, in a similar manner as test
command 25.
Used to enter the copy lead edge adjusting value.
Method:
copy is produced).
NOTE:
Operation must be done in the ready state.
If the PDPL is on, it indicates the assignment of the auto power down function. If not on, the auto
power down function is not assigned. To set the auto power down function active, push the power
down key after the above key operation. Make sure that the PDPL is on. Then, push the PRINT
switch.
To clear the auto power down function, push the power down key. Make sure that the PDPL is out.
Then, push the print switch.
Make a copy is each mode of magnification in the following sequence. x 2.0 > x 0.7 > x 1.22 >x 0.8
>x 1.0
After completion of coping, the copier stays in the ready state in the x 2.0 mode. With the repeat
function, copy may be repeated produce in any magnification ratio.
(Example):
Push 2 > R > PSW in the ready state. This will produce two copies each in the magnification ratio.
NOTE-1:
The doorswitch
must be closed when test com-
'mand, 1, 6, 7, 9, 10, 11, 12, 22, 23, 24, 25, 26,
27, 50, 66, 67 is executed.
If the doorswitch is open, the test command will
not be executed.
If the warmup time is to be checked with the test
command
21, the
doorswitch
must
be closed
after the entry of the test command.
The test command, 40, 41, and 42, corresponds
to inserted developing color. If developing unit is
not inserted
in the machine,
then
check lamp
flickers and the test command
will not be exe-
cuted.

Advertisement

loading