Download Print this page

Sharp SF-7200 Service Manual page 51

Advertisement

[9] Developing unit
AC
Power
(Relay PWB)
ee
eS
EN A
Oe
Re
ee ee er
ee a
t
1
1
i
1
;
ree
1on4
\
10~15
:
CPU
'
1
1
1
'
1
1
t
'
t
1
1
1
!
t
1
i
'
t
:
l
F
I
j
|
'
driver
|
1
!
1
!
'
; (Main PWB)
'
Ay ogee? ck aa, wav cat, Seek ache te ee SRP
Ce
et
ee
See ee
1. Bias Voltage Adjustment
If the bias voltage is not at the proper level (—230+10V), it
must be adjusted in the following manner.
® Remove the rear cover.
@) Connect the multimeter between the bias terminal and
chassis ground of the power supply PWB.
DC power supply PWB
Connector harness
Digital multimeter
TSW1~4 TSG
SF-7200
Connector
(Toner
motor}
Toner hopper
unit
Toner sensor
Developing unit
eee
.
BIAS
PwB
@) Enter test command 25, and adjust the VR1
so that
the bias voltage should be within the given range.
@
Counterclockwise
turn
of the
bias
adjusting
pot
increases the voltage.
®
Clockwise
turn
of the bias adjusting
pot decreases
the voltage.
2. MG Roller Location
@
Install the MG roller with the machined surface of the
roller shaft facing up.
MG adjusting plate
Machined surface
MG roller
9-1