SF-7200
(2) Copy lamp unit (100V series)
Removal of copy lamp unit
@ Remove
the upper right cover, upper left cover, and
the optical cover.
Remove
Remove
"
\
Upper right cover
Upper left |
cover
@
Remove
two
screws that secure the copy lamp unit.
Move
the
copy
lamp
unit
in the arrow
direction.
Remove
the No.1
mirror holding bracket from the
studs.
Remove
8-10
Removal of copy lamp
Remove
the copy
lamp electrode
and
remove
the copy
lamp in the arrow direction.
Electrode holder
Electrode
Remove
Copy lamp
Spacer
installation of copy lamp .
Install the copy lamp with the copy lamp tab located up.
Tab
Copy lamp
f
Reflector
Removal of thermal fuse
Remove
the thermal! fuse holder and remove
the thermal
fuse. Note that a 150°C thermal fuse is used for the 100V
series copier and 109°C fuse for the 200V series copier.
Thermal fuse
Remove
Remove
Cleaning of AE sensor
Do not directly clean the surface of the AE sensor, but
clean the filter.
Wipe the surface of the auto exposure sensor filter with a
cloth dampened with water or alcohol.
NOTE:
Wiping with a dry cloth will impart an electrostatic
charge to the sensor and will attract more dust.