[13] Maintenance
The SF-7200 requires preventive maintenance every 15,000
copies.
1. Parts Replacement
The following is a list of basic maintenance items.
Drum unit (Drum, Drum
cleaner blade, Cleaning
toner pack, Remover tape)
Cleaning roller unit (Clean-
ing roller upper, Cleaning
roller lower)
Heat roller kit (Heat roller
upper, Heat rotler lower,
fa Separator pawl x 3)
| 4 |
Remover arm
5
|
Remover roller
i
DV block, F and R
Corona wire
(in the DV unit)
Table brake
(in the MS5, 6, and 7 holding plate)
aa
3g
Fo
o
ao
=
co
37°
=a
o
a
@ S c 3, =
2. Items Required for Maintenance
(1) Service documents
(2) Test chart and gray scale (UKOG-0089CCZZ)
(3) Service tool kit and digital multimeter
(4)
Replacement parts
(5) Alcohol (isopropy!)
(6) Grease
(UKOG-0062FCZZ)
0107CSZZ2).
(7) Cleaning cloths (use a separate cloth for each of the
following.
optical
system,
corona
wire, and
general
machine cleaning).
(8) DCD test sheet (UKOG-0114FCZZ)
(9) Others
and
Triflon
(UKOG-
60K
SF-7200
3. Maintenance Requirements
(1) Preliminary checks
@ Make
a copy
in the manual
exposure
mode at each
exposure setting. And in the auto exposure mode.
@
Check
the copy quality, general
machine
operation,
and for the presence of any irregular noise.
(2) Component removal before beginning
maintenance.
@
Remove the corona units.
(2) Remove the toner collecting container.
(8) Remove the developing unit and toner hopper.
@
Remove the discharge lamp, blank lamp, and filter.
(8) Remove the exterior panels.
(©) Remove the drum holder unit.
® Remove the drum.
13-1