18.2. Attach the bottom grille
1. Observe the following hooks on the grille rear side.
Hooks for resting on
rubber gaskets
2. Observe the holes that the grille will hang in, and rubber gaskets it will rest on.
Holes
Rubber gaskets
D15514.01 | 2023 OCTOBER | Cisco Room Kit EQX Installation Guide
Hooks for hanging the grille
3. Hang the bottom grille in the holes and let it rest on the rubber gaskets.
4. Fasten the grille with four screws
×2
4x
47
.
(M6x8, Hex 4 mm)