Dell E56S Series Installation And Service Manual page 45

Table of Contents

Advertisement

Next steps
Replace the internal PERC
Installing the internal PERC riser
Prerequisites
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4. Ensure that all internal cables are routed correctly and connected, and no tools or extra parts are left inside the system.
5.
Open the drive
bays, remove
6. Remove the
power supply
7. Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide at
www.dell.com/xcseriesmanuals.
8.
Remove the system
cover.
9.
Remove the air
shroud.
Steps
1. Connect the cable connector to the internal PERC card by aligning it to the guiding pins and replace the screws using a Phillips #2
screwdriver.
Figure 22. Connecting the cable to internal PERC riser
2. Turn over the internal PERC riser and align the internal PERC riser to the PCI slot by holding the blue touch points, and press until fully
seated.
3. Lift the plunger to lock the riser in place.
riser.
Safety
Instructions.
all
drives, and then
close the drive
units.
bays.
Installing and removing system components
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc xc740xd2

Table of Contents