2. Platform Installation
2.4. Installing the Server in a Cabinet

Install server in cabinet using the fixed mount option

Use the procedure below to install the server in the cabinet using fixed mount hardware.
Step
1
Open the cabinet door to access the inside of the cabinet.
2
If the retaining brackets are attached, loosen the two captivated screws on
each bracket and remove them.
3
Verify that the cabinet mounting rails are clear of any installed cables.
4
Using two people, slide the server all the way into the cabinet enclosure
between the mounting railings.
5
Replace the two retaining brackets and tighten the four captivated screws.
6
If necessary, go to Section 2.6 to install an air duct baffle and blank front
panel.
Note: Any unused rack mount space must have an air duct baffle and blank
front panel installed.
7
Go to Section 2.5 to connect the AC power cord and cables to the back
panel of the server.