1.11 Light Industrial Regulatory Compliance; Overview; Electromagnetic Compatibility (Emc); Table 1-15 Emc Specifications (Light Industrial Regulatory) - Honeywell PE SC1430 Planning, Installation And Service Manual

Table of Contents

Advertisement

1.11 Light Industrial Regulatory Compliance

Overview

The compliance specifications in this section apply to installations other than cabinets.
WARNING
Honeywell does not claim Safety Compliance or Electromagnetic Compatibility (EMC)
Compliance for system equipment configurations that have not been described in this
manual as standard system configurations. Any equipment configuration other than
that described in this publication decertifies the Safety and EMC compliance of this
product.

Electromagnetic Compatibility (EMC)

Table 1-15 EMC Specifications (Light Industrial Regulatory)

European Community:
Emissions:
Immunity:
Attention: The following formula is a proximity guideline, for use of Portable
Transceivers
(walkie-talkies) in the frequency range of 80MHz to 1GHz:
D > √{P} (D must be greater than the square root of P)
D = Distance from equipment, in meters.
P = Power Output of the Portable Transceivers (walkie-talkies), in Watts.
Examples:
P = 10 Watts, D > 3.162 meters
P = 5 Watts,
P = 1 Watt,
Note: Electrical cables, which are routed external to the equipment, must be
fully shielded cables (360 degree metallic shielding), in order to comply with the
above EMC standards.
12/2007
PE SC1430-Based Honeywell Server PE SC1430-Based Honeywell Server
Release Independent
IEC 61326, 1997 (Basic Requirements, CISPR11, Class A)
IEC 61326, 1997 (Basic Requirements)
D > 2.236 meters
D > 1.000 meters
Honeywell
1. System Planning
1.11. Light Industrial Regulatory Compliance
29