Site Requirements - Cisco SCE 1000 Installation And Configuration Manual

2xgbe
Hide thumbs Also See for SCE 1000:
Table of Contents

Advertisement

Information About Site Requirement Guidelines

Site Requirements

Table 4-2
Table 4-2
Specification
Temperature
Short term temperatures
Relative humidity
Heat dissipation
1. Short term is defined as not more than 96 consecutive hours, not more than 15 days in one year. 360 hours total in any given
Table 4-3
Approval
EMC
Safety
For more complete information regarding safety and regulatory compliance, refer to the
Compliance and Safety Information for the Cisco Service Control Engines (SCE)
The DC-powered SCE 1000 should be installed in a Restricted Access Location only.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
4-4
and
Table 4-3
contain the site requirement specifications for the SCE 1000.
SCE 1000 Environmental Requirements
1
year, but no more than 15 occurrences in a one-year period.
SCE 1000 Approvals Specifications
Chapter 4 Installation and Maintenance
Acceptable Range
nominal 41°F to 104°F (5°C to 40°C)
23°F to 131°F (-5°C to +55°C)
5% to 95% (non-condensing)
683 BTU/hour
Specification
CE Mark
EMISSIONS: FCC Part 15 CFR 47 Class A,
EN 55022 Class A, CISPR22 Class A, VCCI
Class A, AS/NZS CISPR22 Class A
Immunity - EN 50082-1 EN 55024, CISPR24
(ESD, RFI, EFT, etc.) (Commercial)
UL/CSA 60950, IEC60950, EN60950, AS/NZS,
60950, NOM-019,IEC/EN60825-1, -2,
21CFR1040, 73/23/ECC
Regulatory
document.