Chapter 8 Troubleshooting
Table 8-7
Symptom
GBE link is up
•
(GBE interface link
LED is continuous
green)
•
No traffic received
(GBE interface Rx
LED is not
flashing)
OL-26790-01
Troubleshooting the Link Interface Subsystem (continued)
Diagnostic Action
Problem Solving Using a Subsystems Approach
Possible Cause
No traffic is being
transmitted to the SCE
1000 from its peers.
Auto-negotiation is
disabled at the SCE
1000 but enabled at
peer.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
Possible Solution
Check traffic
connection at peer.
Check auto-negotiation
configuration in the
SCE 1000 and in peer.
See
"How to View the
Gigabit Ethernet
Counters" section on
page
6-7.
8-13