Cisco SCE 1000 Installation And Configuration Manual page 121

2xgbe
Hide thumbs Also See for SCE 1000:
Table of Contents

Advertisement

Chapter 8 Troubleshooting
SCE 1000 Operational Status
Table 8-2
reflects the current SCE 1000 operational status. The operational status can be displayed using CLI
command show system operation-status.
Table 8-2
SCE 1000 Operational Status
Booting
Operational
Warning
Failure
OL-26790-01
lists the operational states of the SCE 1000. The Status LED on the SCE 1000 Front Panel
SCE 1000 Operational States
Description
Initial state after reset
SCE 1000 becomes operational after
completing the following process:
Boot is completed
Power self-tests are completed
without failure
Platform configuration is applied
SCE 1000 is fully operational (as above)
but one of the following occurred:
Line ports (GBE ports) to the link are
down
Management port link is down
Temperature raised above threshold
Voltage not in required range
Fans problem
Power supply problem o Insufficient
space on the disk
Note
System is in Failure state after Boot due to
one of the following conditions:
Power on test failure
Three abnormal reboots in less than 20
minutes
Platform configured to enter Failure
mode consequent to failure-induced
reboot (this is configurable using CLI
command)
Note
Warning Note: If the condition that
caused the SCE 1000 to be in
Warning state is resolved (for
example, link is up) the SCE 1000
reverts to Operational state.
Flashing orange
Depending on the cause of failure,
the management interface and the
platform configuration may or may
not be active/available. Red
Cisco SCE 1000 2xGBE Installation and Configuration Guide
Information About Troubleshooting Tools
Status LED State
Orange
Flashing green
Warning Flashing orange
Red
8-5

Advertisement

Table of Contents
loading

Table of Contents