MX8000-3EX Installation and Operation Guide
Minimum Ringer Off Time is used to determine what the minimum interval is between rings so that the
system will treat two burst separated by a brief pause as one ring.
RErr (Ringer Off Error) – To determine when a new call is received, the system will add the value of ROff,
Min, and this value. When the length of time since the last ring exceeds this sum, the ring will be
considered as a new call. This field is used to enter the amount of time to be added to ROff and Min when
determining if a ring is a new call.
Min# (Minimum Number of Ringer Periods – This field is used to define the number of valid rings that must
be received before the system accepts the call as valid (answers).
To Change the Ring Options:
1. Follow the procedures in Section 5.4.2.
5
2. Press
for Miscellaneous Line Options menu.
3. Press
until the display flashes on the <Ring Opt> field.
ENTER
4. Press
MENU .
5. The display flashes on the Minimum Ring Period (MinR) field.
6. Enter a value from 15 to 99 ms for the Minimum Ring Period.
7. Press
to advance to the Max Ring Period (Max) field.
8. Enter a value from 015 to 100 ms for the Maximum Ring Period.
9. Press
to advance to the Ringer Off Time (ROff) field.
10. Enter a value from 1500 to 8000 ms for the Ringer Off Time.
11. Press
to advance to the Min Ring Off (Min) field.
12. Enter a value from 100 to 800 ms for the Minimum Ring Off Time.
13. Press
to advance to the Ringer Off Error (RErr) field.
14. Enter a value from 0800 to 4400 ms for the Ringer Off Error Time.
15. Press
to advance to the Min # of Ring Periods (Min#) field.
16. Enter a value from 01 to 20 periods for the Minimum Number of Ringer Periods.
17. To exit press
To Change the Call Hang-Up Time:
Notes:
If the Event Release setting (see page 5–26) is "greater" than the Call Hang-Up setting, the receiver will
not disconnect the line (panel) until the Event Release time has expired.
The actual amount of time before the receiver disconnects a line may at times be greater than the
actual programmed value for Call Hang-Up Time. An event in progress (Event Release) has to
complete before the call hang-up takes affect.
1. Follow the procedures in Section 5.4.2.
5
2. Press
for Miscellaneous Line Options menu.
5–44
.