MX8000-3EX Installation and Operation Guide
8.7

FBII CP-220 Automation Protocol

8.7.1

3x1, 4x1, and 4x2 Automation Protocols

When the MX8000–3EX receives a 3x1, 4x1, and 4x2 transmission operating in the CP-220 mode, the output
protocol to the computer is as shown in Figure 8–6.
8.7.2

Acron 11 Digit with Zero or Space

When the MX8000–3EX receives an Acron fast transmission while operating in the CP-220 mode, the output
protocol to the computer is as shown in Figure 8–7.
When a 3-digit account number is received, the MX8000–3EX will send a zero or a space in place of the first
digit of the account number, dependent on the setting programmed into the receiver.
When in Radionics or ADEMCO modes, the MX8000–3EX will send an illegal format message to the
computer since it does not accept this format when in these modes.
8.7.3

FBII Superfast

When the MX8000–3EX receives an FBII Superfast transmission while operating in the CP-220 mode, the
output protocol to the computer is as shown in Figure 8–8.
A space will be sent as the zone digit any time that the MX8000–3EX receives a zero or letter a for the zone
digit.
8.7.4
CP-220 Contact ID
When the MX8000–3EX receives a Contact ID ® (also referred to as Point ID – PID) transmission while
operating in the CP-220 mode, the output protocol to the computer is as shown in Figure 8–9.
8–22
HRG123422T
PROGRAMMABLE TERMINATOR
EVENT CODE
ACCOUNT NUMBER
GROUP NUMBER
RECEIVER NUMBER
PROGRAMMABLE HEADER
Figure 8–6: CP-220 3x1, 4x1, 4x2 Protocol
RGAAAAZZZZZZZZT
TERMINATOR
ZONE STATUS FOR ZONES 1 THROUGH 8
ACCOUNT NUMBER (4 DIGITS)
GROUP NUMBER
RECEIVER NUMBER
Figure 8–7: CP-220 Acron 11 Digit Protocol
RG12341121T
PROGRAMMABLE TERMINATOR
EVENT DIGIT
HEXIDECIMAL ZONE NUMBER (2 DIGITS)
ALARM TYPE
ACCOUNT NUMBER
GROUP NUMBER
RECEIVER NUMBER
Figure 8–8: CP-220 FBII Superfast Protocol