Communications
Choices
Menu
Baud
D (# Data Bits)
Com Port 1
S (# Stop Bits)
P (Parity)
PortMon (Port
Monitor)
F (Flow)
Init Str
(Initialization
String)
Com Port 2
Edit Init Str
Par Port (Parallel
(Initialization
Port)
String)
Format
Automation Cfg
Hex
Heartbeat
Time (of
Heartbeat)
Table 5–5: Communications Options and Description (cont'd)
Options
38400
19200
9600
7200
4800
2400
1200
600
300
110
7
8
1
2
Even
Odd
No
Yes
No
Hdwr
Sfwr
None
SK9000
ADEM 8000
ITI Gen
ITIComp
ADEM 685
FBII 220
CAPS
Y = Enabled
N = Disabled
Y = Enabled
N = Disabled
10-600 seconds
Default
When set to Yes (recommended) the computer ready
line is monitored.
Unidirectional communication
No supervision
Two 20-character ESC command sequences.
See Section 5.3.3.4 for step-by -step instructions.
Same as Com Port 1
Two 20-character ESC command sequences.
See Section 5.3.3.4 for step-by -step instructions.
See Section 5.3.3.5 for programming steps.
See Section 8 for more information on automation
formats.
When Hex Mode is enabled, any call data that is
determined to be bad data will be output in Hex format.
Only visible if ADEM 8000 or SK9000 format is
selected.
See Section 5.3.3.5 for programming steps.
45 sec
How often a supervisory signal (a heartbeat) is sent to
the automation computer. See Section 5.3.3.5 for
programming steps.
Section 5 – Programming
Comments
5–13