LFRG 1234 NNNN NNNN NCR
8.5.4

685 Contact ID

When the MX8000–3EX receives a Contact ID ® (also referred to as Point ID – PID) transmission while
operating in the 685 mode, the output protocol to the computer is as shown in Figure 8–4.
LFRG 1234 18 QXYZ GG FCCC CR
ADEMCO DTMF formats will not transmit a true TouchTone "0" therefore, all "A"s are converted to 0 (zero)
prior to output. The code string contains spaces at the points shown in Figure 8–4.
Contact ID Event Definition Codes are provided in Table 8–23.
8–14
TERMINATOR (ASCII CARRIAGE RETURN - HEX 0D)
CHANNEL REPORT CODE, CHANNEL 9
SPACE (ASCII SPACE CHARACTER - HEX 20)
CHANNEL REPORT CODE, CHANNELS 5-8
SPACE (ASCII SPACE CHARACTER - HEX 20)
CHANNEL REPORT CODE, CHANNELS 1-4
SPACE (ASCII SPACE CHARACTER - HEX 20)
ACCOUNT NUMBER
SPACE (ASCII SPACE CHARACTER - HEX 20)
GROUP NUMBER
RECEIVER NUMBER
HEADER (ASCII LINE FEED - HEX 0A)
Figure 8–3: 685 ADEMCO High Speed Protocol
TERMINATOR (ASCII CARRIAGE RETURN - HEX 0D)
SPACE (ASCII SPACE CHARACTER - HEX 20)
3 DECIMAL DIGITS REPRESENTING CONTACT OR USER
DEFINES CCC. C = CONTACT, U = USER.
SPACE (ASCII SPACE CHARACTER - HEX 20)
2 DIGIT GROUP NUMBER
SPACE (ASCII SPACE CHARACTER - HEX 20)
EVENT DEFINITION CODE
EVENT CHARACTER WHERE
E = EVENT, NEW ALARM/OPENING
R = RESTORE/CLOSING
SPACE (ASCII SPACE CHARACTER - HEX 20)
DEDICATED IDENTIFIER FOR CONTACT ID
SPACE (ASCII SPACE CHARACTER - HEX 20)
4 DECIMAL DIGIT ACCOUNT NUMBER
SPACE (ASCII SPACE CHARACTER - HEX 20)
RECEIVER GROUP NUMBER (0-9)
RECEIVER NUMBER (0-9)
HEADER (ASCII LINE FEED - HEX 0A)
Figure 8–4: 685 Contact ID Protocol