19 SCAN
19.8 Common Functions for Scan
Power-on Scan
Power-on Scan is a function to be used to automatically start scanning when the transceiver is turned ON.
 NX-200/ NX-200S/ NX-300/ NX-300S
If "Zone Select" is configured for the Selector, the transceiver starts the scan according to the configuration for Scan
Type for the zone number indicated by the pointer of Selector when the transceiver is turned ON. If the zone number
indicated by the pointer of the Selector is not configured for the transceiver, the scan pauses.
If anything other than "Zone Select" is configured for Selector, the transceiver starts the scan according to the
configuration for Scan Type for the zone selected when the transceiver is turned ON.
 NX-210/ NX-410/ NX-411/ NX-700/ NX-700H/ NX-800/ NX-800H/ NX-900/ NX-901
The transceiver starts the scan according to the configuration for Scan Type for the zone selected when the transceiver
is turned ON.
Configuration using KPG-111D/ DN
Configuring the Power-on Scan to be enabled or disabled (
Selected CH/GID Scan
Selected CH/GID Scan is a function that is used to add the selected channel or GID to the target channels or GIDs for
scanning even if it is not configured to be scanned.
Configuration using KPG-111D/ DN
Configuring the Selected CH/GID Scan to be enabled or disabled (
Starting Scanning by Linking with the Microphone (Off-hook Scan) (Mobile Only)
Off-hook Scan is a function to start scanning regardless of the microphone hook status.
The transceiver scans according to the configuration for Off-hook Scan.
Configuration
Enabled
Pressing the Scan key causes the transceiver to start scanning regardless of the microphone On- or Off-hook state.
If the microphone is in the On-hook state, pressing the Scan key causes the transceiver to start scanning; however
if the microphone is in the Off-hook state, the transceiver cannot start scanning. If the microphone changes from the
Disabled
On-hook state to Off-hook state in Scan Mode, the scan pauses on the Revert Channel or GID. When the
microphone goes to On-hook state, the transceiver resumes scanning.
Configuration using KPG-111D/ DN
Configuring the Off-hook Scan to be enabled or disabled (
FUNC (K)/Ver 4.00
See
FPRG 8.13.1 Scan Tab)
See
Table 19-4 Off-hook Scan
Description
See
FPRG 8.13.1 Scan Tab)
FPRG 8.13.1 Scan Tab)