Binary inputs and outputs
Name
OscillationCntOff 3
OscillationTimeOn3
OscillationTimeOff3
Threshold4
DebounceTimeOn4
DebounceTimeOff4
OscillationCntOn4
OscillationCntOff4
OscillationTimeOn4
OscillationTimeOff4
Threshold5
DebounceTimeOn5
DebounceTimeOff5
OscillationCntOn5
OscillationCntOff5
OscillationTimeOn5
OscillationTimeOff5
Threshold6
DebounceTimeOn6
DebounceTimeOff6
OscillationCntOn6
OscillationCntOff6
OscillationTimeOn6
OscillationTimeOff6
Threshold7
DebounceTimeOn7
DebounceTimeOff7
OscillationCntOn7
OscillationCntOff7
OscillationTimeOn7
OscillationTimeOff7
Threshold8
DebounceTimeOn8
DebounceTimeOff8
OscillationCntOn8
OscillationCntOff8
OscillationTimeOn8
OscillationTimeOff8
Table continues on next page
36
Values (Range)
Unit
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
15 - 221
-
0.0000 - 0.1270
-
0.0000 - 0.1270
-
0 - 255
-
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
15 - 221
-
0.0000 - 0.1270
-
0.0000 - 0.1270
-
0 - 255
-
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
15 - 221
-
0.0000 - 0.1270
-
0.0000 - 0.1270
-
0 - 255
-
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
15 - 221
-
0.0000 - 0.1270
-
0.0000 - 0.1270
-
0 - 255
-
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
15 - 221
-
0.0000 - 0.1270
-
0.0000 - 0.1270
-
0 - 255
-
0 - 255
-
0.000 - 600.000
-
0.000 - 600.000
-
© 2021 Hitachi Energy. All rights reserved.
Step
Default
1
0
0.001
0.000
0.001
0.000
1
65
0.0001
0.0050
0.0001
0.0050
1
0
1
0
0.001
0.000
0.001
0.000
1
65
0.0001
0.0050
0.0001
0.0050
1
0
1
0
0.001
0.000
0.001
0.000
1
65
0.0001
0.0050
0.0001
0.0050
1
0
1
0
0.001
0.000
0.001
0.000
1
65
0.0001
0.0050
0.0001
0.0050
1
0
1
0
0.001
0.000
0.001
0.000
1
65
0.0001
0.0050
0.0001
0.0050
1
0
1
0
0.001
0.000
0.001
0.000
1MRK 511 557-UEN Rev. A
Description
OscillationCountOff for input 3
OscillationTimeOn for input 3
OscillationTimeOff for input 3
Threshold in percentage of station
battery voltage for input 4
Debounce time On for input 4
Debounce time Off for input 4
OscillationCountOn for input 4
OscillationCountOff for input 4
OscillationTimeOn for input 4
OscillationTimeOff for input 4
Threshold in percentage of station
battery voltage for input 5
Debounce time On for input 5
Debounce time Off for input 5
OscillationCountOn for input 5
OscillationCountOff for input 5
OscillationTimeOn for input 5
OscillationTimeOff for input 5
Threshold in percentage of station
battery voltage for input 6
Debounce time On for input 6
Debounce time Off for input 6
OscillationCountOn for input 6
OscillationCountOff for input 6
OscillationTimeOn for input 6
OscillationTimeOff for input 6
Threshold in percentage of station
battery voltage for input 7
Debounce time On for input 7
Debounce time Off for input 7
OscillationCountOn for input 7
OscillationCountOff for input 7
OscillationTimeOn for input 7
OscillationTimeOff for input 7
Threshold in percentage of station
battery voltage for input 8
Debounce time On for input 8
Debounce time Off for input 8
OscillationCountOn for input 8
OscillationCountOff for input 8
OscillationTimeOn for input 8
OscillationTimeOff for input 8
Technical Manual