[Cd.7] M code OFF request
• The M code ON signal turns OFF.
• After the M code ON signal turns OFF, "0" is stored by the Motion module automatically. (Indicates that the OFF request is
completed.)
Fetch cycle: Operation cycle
■Setting value
• Set with a decimal.
Setting value
1
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
[Cd.8] External command valid
Validates or invalidates external command signals.
Fetch cycle: At request by external command signal
■Setting value
• Set with a decimal.
Setting value
0
1
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
[Cd.9] New current value
When changing the feed current value using the start No. "9003", use this data item to specify a new feed value.
Fetch cycle: At change request
■Setting range
• Set with a decimal.
• The setting value range differs according to "[Pr.1] Unit setting".
Setting of "[Pr.1] Unit setting"
0: mm
1: inch
2: degree
3: pulse
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
Downloaded from
ManualsNet.com
search engine
Details
M code ON signal turns OFF
Details
Invalidates an external command.
Validates an external command.
Value set with a program (unit)
-1
-2147483648 to 2147483647(  10
-5
-2147483648 to 2147483647 (  10
-5
0 to 35999999 (  10
degree)
-2147483648 to 2147483647 (pulse)
12 DATA USED FOR POSITIONING CONTROL
mm)
inch)
12.8 Control Data
12
521