[Md.43] Start data pointer being executed
• This area stores a point No. (1 to 50) attached to the start data currently being executed.
• This area stores "0" after completion of a positioning operation.
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.44] Positioning data No. being executed
• This area stores a positioning data No. attached to the positioning data currently being executed.
• The value stored is 1 to 600, and 9001 to 9003.
• This area stores "0" when the JOG/inching operation is executed.
• This area stores "1" during the JOG operation or the positioning operation from the test mode. For details, refer to the
following. Page 351 Test mode
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.45] Block No. being executed
• When the operation is controlled by "block start data", this area stores a block No. (7000 to 7004) attached to the block
currently being executed.
• At other times, this area stores "0".
Refresh cycle: At start
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.46] Last executed positioning data No.
• This area stores the positioning data No. attached to the positioning data that was executed last time.
• The value stored is 1 to 600, and 9001 to 9003.
• The value is retained until a new positioning operation is executed.
• This area stores "0" when the JOG/inching operation is executed.
• This area stores "1" when the JOG operation or the positioning operation from the test mode is executed. For details, refer
to the following. Page 351 Test mode
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
12 DATA USED FOR POSITIONING CONTROL
498
12.7 Monitor Data
Downloaded from
ManualsNet.com
search engine