[Md.43] Start data pointer being executed
• This area stores a point No. (1 to 50) attached to the start data currently being executed.
• This area stores "0" after completion of a positioning operation.
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.44] Positioning data No. being executed
• This area stores a positioning data No. attached to the positioning data currently being executed.
• The value stored is 1 to 600, and 9001 to 9003.
• This area stores "0" when the JOG/inching operation is executed.
• This area stores "1" during the JOG operation or the positioning operation from the test mode. For details, refer to the
following. Page 351 Test mode
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.45] Block No. being executed
• When the operation is controlled by "block start data", this area stores a block No. (7000 to 7004) attached to the block
currently being executed.
• At other times, this area stores "0".
Refresh cycle: At start
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.46] Last executed positioning data No.
• This area stores the positioning data No. attached to the positioning data that was executed last time.
• The value stored is 1 to 600, and 9001 to 9003.
• The value is retained until a new positioning operation is executed.
• This area stores "0" when the JOG/inching operation is executed.
• This area stores "1" when the JOG operation or the positioning operation from the test mode is executed. For details, refer
to the following. Page 351 Test mode
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
12 DATA USED FOR POSITIONING CONTROL
498
12.7 Monitor Data