Removing The Cdp Control Panel; Communication With Amc Circuit Board - ABB ACS5000 User Manual

Water-cooled (generation 2)
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

10.4. Removing the CDP control panel

When the CDP control panel must be removed from its mounting cradle, follow the
instructions below.
1. When the panel is removed while the drive is in operation, check the setting of parameter
31.01 PANEL LOSS SUPERVISION first.
If the parameter is set to NOT USED , the panel can be removed without interrupting drive
operation.
For more information on parameter settings, see "Appendix G – Signal and
parameter table".
2. To remove the panel, proceed as illustrated.
IMPORTANT! If you remove the CDP control panel during operation, you can only stop the
drive by pressing the emergency-off push button.
The green LED (1) signals that the control voltage has been switched on.

10.4.1. Communication with AMC circuit board

The CDP control panel (1) is connected to the AMC circuit board (2) via an RS485 interface.
1
PRODUCT
ACS5000W gen. 2
2
DOCUMENT KIND
User manual
PREVENTIVE AND CORRECTIVE MAINTENANCE
DOCUMENT ID.
3BHS799208 E01
1
REV.
LANG.
PAGE
J
en
164/186

Advertisement

Table of Contents
loading

Table of Contents