9.1.2. Functions

The CDP control panel serves as the basic user interface for operating and monitoring the drive
when the local operating mode has been selected.
The CDP control panel can be attached to or detached from the drive without having to switch
off the auxiliary power supply first.
Using the CDP control panel, it is possible to:
Enter startup data
Enter reference values
Enter start, stop and direction commands
Display actual values (three values can be read simultaneously)
Display and adjust parameters
Display information on the most recent 64 fault events

9.2. Modes

The CDP control panel provides the following modes:

Identification mode

Actual signals mode
Parameters mode
Functions mode
Drive mode (not used)
9.2.1. Identification mode
The identification mode informs the user about the CDP control panel version and the ID
number of the drive. The information appears on the display
when the power supply is switched on, or
when the CDP control panel is connected to the drive and the auxiliary voltage has been
switched on already.
When the CDP control panel is initialized, the display changes as follows:
CDP312 PANEL V5.30
...........
PRODUCT
ACS5000W gen. 2
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS799208 E01
CDP CONTROL PANEL
REV.
LANG.
PAGE
J
en
139/186