8.5.1.1. Display values
The actual values shown on the display can be freely selected. The following default values are
shown on the display when the panel is in local control mode:
–
Motor current in percent (%)
–
Actual armature voltage in V
–
Actual converter current in A (rectified AC current value)
NOTE – In remote control mode, the START and STOP keys do not work.
8.5.2. Resetting alarm and fault messages
Alarm messages: cannot be reset by pressing the reset soft key. The alarm resets
–
automatically as soon as the reason causing the alarm has been resolved.
Fault messages: must be reset manually after the reason causing the fault has
–
been resolved. The message on the display can be reset either by pressing the reset soft key
on the EXU control panel, or by pressing the reset button on the control panel of the drive.
8.5.3. Parameter settings
Parameters are set and verified during commissioning to ensure the EXU operates correctly.
NOTICE
Risk of component damage! Running the EXU with incorrect parameters can damage the
equipment, result in faulty operation of the drive system, and reduce control accuracy.
→ DO NOT change a parameter if you do not understand the parameter and the effects of the
change
8.6. Lamp-test function
The lights and illuminated push buttons on the control compartment can be tested with the
lamp-test function. The lamp test is activated via the CDP control panel by setting control
parameter 16.7 to LAMP TEST. The lamp-test function resets itself after a set time.
8.7. Status messages
The following section lists the status messages of the main operating states that the drive
passes through when:
–
Drive is put into operation (see Section 8.7.1, "Start sequence of the drive", page 127)
–
Drive is stopped (see Section 8.7.2, "Stop sequence of the drive", page 128)
–
Fault condition has occurred
The status messages are sent to the higher-level control system and are displayed on the CDP
control panel of the drive.
For information on other status messages (eg, fault status messages), see the status words in
"Appendix G – Signal and parameter table".