MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Before attempting to use, visually check the lifting brackets and associated rack hardware for
damage that may have occurred during transit. If any damage is apparent, contact Motorola for
replacement. Correct lifting bracket tightness and alignment are crucial to ensure that the lifting
bracket assembly will perform to its intended lifting capacity.
Both lifting brackets must be used when lifting the equipment rack. When lifting from a center
point, the distance measured between the lifting point and the top surface of the cabinet must be
minimum 350 mm to ensure that the proper lifting angle is maintained (see
length shorter than that specified could cause the lifting brackets to fail.

Figure 4-1 Lifting Point for MTS 4 and Expansion Cabinet

If lifting brackets are removed or become loose, they must be properly installed before
they are used to lift the equipment rack.
When placing the MTS 4 cabinet back on the floor, it can be easily decided whether to put it
in the vertical (A) or horizontal (B) position, see
6802800U74-N September 2009
Lifting the MTS 4 and Expansion Cabinet