Base Radio Alarms
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_PA_VSWR_ALARMING
ALM_TX_REFL_PWR_ALM_FAULT Reflected power
ALM_PA_REFL_PWR_FAULT
ALM_TX_REFL_PWR_ALM_WARN Reflected power
ALM_PA_REFL_PWR_WARN
ALM_TX_KEYED_FWD_PWR
_LOW
ALM_PA_OTHER_RF_FAIL
ALM_TX_KEYED_FWD_PWR
_HIGH
ALM_BRC_ETH_LAN1_LINK
_ALM
13-34
Recovery
Description
Action
The same as ALM_TX_VSWR_ALARMING
BRC is de-keyed
is high.
by the software.
The same as ALM_TX_REFL_PWR_ALM_FAULT
The output
is high.
power is reduced
by the software.
The same as ALM_TX_REFL_PWR_ALM_WARN
The output
The power
power dropped
leveling
below 60%
procedure is
of the
executed to get
current target
the output power
(programmed)
to the expected
power (the
level.
power level that
is expected to be
currently set).
The same as ALM_TX_KEYED_FWD_PWR_LOW
The output
The power
power rose
leveling
above 140%
procedure is
of the
executed to get
current target
the output power
(programmed)
to the expected
power (the
level.
power level that
is expected to be
currently set).
Ethernet LAN1
No recovery
action taken by
Link is down
the software.
- the link
state change
is reported by
CPLD by the
interrupt (Host
IRQ2).
Chapter 13: MTS Troubleshooting
Clear Action
BRC is re-keyed
The alarm may be
by the software.
reported because
If the alarm
of the BRC
condition
hardware failure
disappears after
or configuration
key-up then the
problems.
alarm is cleared.
If the alarm
The alarm may be
condition
reported because
disappears then
of the BRC
the output power
hardware failure
is restored by the
or configuration
software to the
problems.
target level.
When the output
The alarm may be
power is restored
reported because
to the expected
of the BRC
level the alarm is
hardware failure
cleared
or configuration
problems.
When the output
The alarm may be
power is restored
reported because
to the expected
of the BRC
level the alarm is
hardware failure
cleared
or configuration
problems.
When the link is
The link to Site
up then the alarm
Controller is
is cleared.
disconnected or
failed.
6802800U74-N September 2009
Notes