LED Fault Indications

LED Fault Indications
Table 13-1
Indication
All LEDs: OFF
Active LED: Amber, BTS
Alarm LED: RED
Active LED: GREEN
Mode LED: GREEN
BTS Alarm LED: RED
GPS LED: GREEN
Active LED: Amber
Active LED: RED
GPS LED: RED
BTS Alarm: Amber
13-2
Site Controller LED Fault Indications
Possible Failure
Power Supply switch is
OFF or power supply is
damaged
Application started
after Booting, or failed
activation, SC not active
WAT (Wide Area Trunking)
with problem Eg. IAC,
E1/X.21 relay not energized
Inactive, Site Controller
standby
Failed Site Controller or
power up
No GPS signal, no
connection to remote
GPS, or non-synchronized
mode
CAN Bus problems,
External Alarms,
Chapter 13: MTS Troubleshooting
Corrective Action
- Check if power supply switch is ON
- Verify power to the Site Controller cabling
- Check LEDs on PS (power supply)
- Replace PS (power supply)
If it is not booting / startup phase:
- Check the Standby Site Controller cabling,
connections to all units
- Check its status of ports and links
- Check status of appropriate frus: atcc, dpm,
psu (see can bus problems)
- Check ports and links state: port, in case of
problems check all cabling connections
- Check the status of IAC inputs status
- Check site link failure: .sitelink, status sc
- Check cabling, replace cabling if needed
- Replace FRU
- Check if GPS antenna is connected
- Check status sri
Canbus problems:
- Check canbus registration table: can
check_mapping*
- Verify the registration table with existing
FRU configuration.
- If units not present exist, check cabling
(caution: all units connected in series). try to
reset or reboot can reset*, can reboot*
- If didn't help may try to upgrade units
software or replace faulty unit
- If units not present doesn't exist – remove
entry from registration table
- If track id not mapped probably registration
table not properly updated
Error detected:
- Get appropriate unit status / alarm to see
details about possible alarm cause
- If cause is in wrong configuration (wrong
VSWR thresholds or fans not started) modify
it. If alarms are considerably higher than
the default values, investigate a potential
hardware issue with the ATCC.
- If FRU doesn't work properly, try to upgrade
6802800U74-N September 2009