MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 5-2 AC/DC Power Cabling for MTS 4
Index
1a
3066551B01
1b
2
3066553B01
3
3066553B01
4a
3066545B01
4b
4c
4d
5a
5b
3066545B01
5c
5d
6
3066556B02
7
3066556B02
8
3066557B01
9
3066557B01
10
306659B01
6802800U74-N September 2009
Cable Part
From Unit/
Number
Connection Name
Junction Panel/ DC1
Junction Panel/ DC2
Junction Panel/ AC In 1
Junction Panel/ AC In 2
Power Supply Unit 1/
DC Out
Power Supply Unit 2/
DC Out
Junction Panel/
Bat Temp. 1
Junction Panel/
Bat Temp. 2
Power Supply Unit 1/
ATCC DC Out
Power Supply Unit 2/
ATCC DC Out
ATCC 1/Inside ATCC
Interconnection
To Unit/ Connection
Name
Power Supply Unit 1/
DC In Battery
Power Supply Unit 2/
DC In Battery
Power Supply Unit 1/
AC In
Power Supply Unit 2/
AC In
Base Radio 1/ DC In
Base Radio 2/ DC In
Site Controller 1/ Power 1 Pins: 7 and 14
Site Controller 2/ Power 1 Pins: 7 and 14
Base Radio 3/ DC In
Base Radio 4/ DC In
Site Controller 2/ Power 2 Pins: 7, 14
Site Controller 1/ Power 2 Pins: 7, 14
Power Supply Unit 1/
Battery Temp. Sens.
Power Supply Unit 2/
Battery Temp. Sens.
ATCC 1/ DC In
ATCC 2/ DC In
ATCC 2/Inside ATCC
Interconnection
AC/DC Power Cabling
Notes
N/A
N/A
With retaining clip
With retaining clip
Pins: 1, 2, 3, 8, 10, and
11
Pins: 4, 5, 6, 9, 12, and
13
Pins: 1, 2, 3, 8, 10, and
11
Pins: 4, 5, 6, 9, 12, and
13
N/A
N/A
Only for configuration
with ATCC
Only for configuration
with two ATCCs
Only for configuration
with two ATCCs
5-3

Hide quick links: