Figure 13-1 Site Controller Leds; Table 13-1: Site Controller Led Fault Indications - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 13-1
Indication
BR1 or BR2 or BR3 or
BR4 or Service LED: OFF
E1 LEDs: Amber
E1 LEDs: RED

Figure 13-1 Site Controller LEDs

6802800U74-N September 2009
Site Controller LED Fault Indications (Continued)
Possible Failure
Ethernet link not present
Errors FE, CRC, BPV, PD
Primary E1 failure LOS,
Link down
LED Fault Indications
Corrective Action
code, or reset unit
- If problem still exists replace faulty unit
with new one
BR configured loss:
- Check state of BRs (br configured is missing)
status sc -all, status br
*) Canbus commands
- Check if Ethernet cable is connected
- If still no LED indication, replace the cable
- Verify the cabling
- Check if the cable is plugged to right
connector
- Replace E1 cable if no change
- status bsl
- Verify the cabling
- If no change replace E1 cable
13-3