7.7 Interrupt Settings

Set conditions for sending an interrupt request to the CPU module.
(1) Setting procedure
Item
Input Format
Select the input format of the "Word Device Setting Value" field.
Device Code
Set an interrupt condition device.
Device No.
Detection Method
Select the detection timing of an interrupt generated by the device set
in "Device Code" and "Device No.".
Interrupt Condition
Word Device Setting
When "RWw", "RWr", or "SW" is selected in "Device Code", enter a
Value
word device value that triggers an interrupt.
Channel No./Connection
This item cannot be set for the Simple Motion module.
No.
Enter an interrupt (SI) number used in "Interrupt Pointer Setting" of the
PLC parameter window. (Refer to Section 7.7 (3).)
Interrupt (SI) No.
An interrupt (SI) number is a management number assigned to each
Simple Motion module. This number is required when the Simple
Motion module sends an interrupt request to the CPU module.
1) Set network setting parameters. (Refer to Section 7.3.)
2) Open the setting window.
Project window
[Ethernet/CC IE/MELSECNET]
3) Set parameters in the window.
Up to 16 interrupt conditions can be set.
4) Click the [End] button.
Description
[Parameter]
[Network Parameter]
[Interrupt Settings] button
7 - 25
Chapter 7 PARAMETER SETTING
Setting range
DEC, HEX
(Default: DEC)
Refer to the next table.
Remark