Mitsubishi Electric MELSEC-Q Series User Manual page 190

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

(2) Link device assignment
(a)
CPU module
Master station
X
1000
0000
L60DA4
100F
1010
LX40C6
101F
1020
(Unused)
102F
1030
10FF
00FF
Y
1000
0000
L60DA4
100F
1010
(Unused)
101F
1020
LY10R2
102F
1030
10FF
00FF
(b)
CPU module
W
1000
Warning
1008
output flag
Latest
1010
error code
10FF
W
0
CH1
1
Digital value
CH2
2
Digital value
FF
RX and RY assignment
Head module
RX
0000
L60DA4
000F
0010
LX40C6
001F
0020
(Unused)
002F
0030
00FF
RY
0000
L60DA4
000F
0010
(Unused)
001F
0020
LY10R2
002F
0030
00FF
RWr and RWw assignment
Master station
RWr
0
0
FF
FF
RWw
0
0
FF
FF
L60DA4
X
X
0
F
Y
Y
0
F
Start I/O No.
0000H
Head module
RWr
W
RWw
W
11 - 4
Chapter 11 PROGRAMMING
LX40C6
X
10
1F
Start I/O No.
0010H
L60DA4
Buffer memory
1000
Warning
30H(48)
output flag
Latest
13H(19)
error code
10FF
0
CH1
1H(1)
Digital
value
CH2
2H(2)
Digital
value
FF
LY10R2
Y
20
2F
Start I/O No.
0020H

Advertisement

Table of Contents
loading