(c) Supplementary Setting
[CC IE Field Configuration]
Item
Set "Link Scan Mode Setting", "Loopback Function Setting", "Block
Data Assurance per Station", and "Operation Setting for
Returning".
Supplementary
Setting
(1) Link Scan Mode Setting
This item cannot be set for the Simple Motion module.
(2) Loopback Function Setting
This item cannot be set for the Simple Motion module.
(3) Block Data Assurance per Station
Select whether to assure data integrity on a station basis in link
refresh between the CPU module and the Simple Motion
module. (Refer to Section 8.3.4.)
(4) Operation Setting for Returning
This item cannot be set for the Simple Motion module.
[Supplementary Setting]
Description
7 - 13
Chapter 7 PARAMETER SETTING
Setting range
• Link Scan Mode Setting:
All invalid.
• Loopback Function Setting:
All invalid.
• Block Data Assurance per
Station:
Selected (Assure Block Data)/
not selected
(Default: Selected (Assure
Block Data))
• Operation Setting for Returning:
All invalid.
Remark
• "Block Data
Assurance per
Station" is a
function for the
station No.17 to
120.