7.6 Refresh Parameters

Set link refresh ranges between the link devices of the Simple Motion module and the
devices of the CPU module.
(1) Setting procedure
Item
Select a link device assignment method.
Assignment Method
• Points/Start: Enter the points and start numbers of link devices.
• Start/End: Enter the start and end numbers of link devices.
Set the link refresh ranges of SB and SW. One range can be set for
each SB and SW. (Refer to Section 8.3.2.)
(Example)
Dev. Name
Transfer SB
Transfer
SW
Points,
Start, End
1) Set network setting parameters. (Refer to Section 7.3.)
2) Open the setting window.
Project window
[Ethernet/CC IE/MELSECNET]
3) Set parameters in the window.
4) Click the [End] button.
Description
0000H
Device
to
name
(SB)
01FFH
0000H
Device
name
to
(SW)
01FFH
Simple Motion module
[Parameter]
[Network Parameter]
[Refresh Parameters] button
0000H
Device
to
name
(SB)
01FFH
0000H
Device
to
name
(SW)
01FFH
CPU module
7 - 21
Chapter 7 PARAMETER SETTING
Setting range
• Points/Start
• Start/End
(Default: Start/End)
(1) Transfer SB
• Link Side: Fixed at
"SB".
• PLC Side: M, L, B, D,
W, R, SB, ZR
(2) Transfer SW
• Link Side: Fixed at
"SW".
• PLC Side: M, L, B, D,
W, R, SW, ZR
(Default: Blank)
• Link Side: 0 to 1FFH
• PLC Side: Within
device range of CPU
module
(Default: Blank)
Set bit devices in
increments of 16 points
and word devices in
increments of 4 points.
Remark