Mitsubishi Electric MELSEC-Q Series User Manual page 117

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

3) When the following window opens, select the Simple Motion module to be
diagnosed and click the [OK] button to start the CC-Link IE Field Network
diagnostics.
Modules are listed in the order configured in network settings. (Refer to Section
7.3.)
POINT
When multiple Simple Motion modules of the same network number are mounted
on the same base unit, the module with the smallest start I/O number is always
diagnosed, regardless of setting.
4) Select the station to be diagnosed from "Select Station" or "Network Status".
,
, or
is displayed on the module icon of the station where an error
occurs.
• A disconnected station that had performed data link is indicated with the
icon in the network map.
A disconnected station that has been set in the network configuration settings but
has not yet performed data link is displayed on the right end of the area.
However, even if a disconnected station had performed data link, it is displayed
on the right end of the area in the following cases.
• A station that was reconnected to a network after cable disconnection/insertion
or power-off and power-on of the system and remains disconnected
• A disconnected station with the station icon deleted in the network map by
clicking the [Update...] button
is displayed on the icon of a cable where a communication error occurs. To
check the details of the communication error, click the neighboring stations of
is displayed if the network is configured in ring topology.
Chapter 9 CC-LINK IE FIELD NETWORK DIAGNOSTICS
9 - 5
Disconnected station
.