Mitsubishi Electric MELSEC-Q Series User Manual page 263

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Number
Name
SW0181
Reserved station
to
cancel setting status
SW0187
Synchronous
SW01C0
communication
to
function information
SW01C7
(each station)
Synchronous/
asynchronous
SW01C8
to
operation status
SW01CF
information (each
station)
Stores if a reserved station setting is temporarily canceled.
0: No reserved station setting cancel
1: Reserved station function disable in progress
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0181
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0182
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0183
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0184
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0185
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0186
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
__
__
__
__
__
SW0187
Each number in the table represents a station No.
__
(Conditions)
• This is enabled when Baton pass status (own station) (SB0047) is off.
• Holds the data immediately before the error.
• This is enabled only for normal stations in Baton pass status (each station) (SW00A0 to
SW00A7).
• Stations higher than the maximum station No. are ignored.
Stores the setting information of synchronous/asynchronous communication of the synchronous
communication function for each station.
0: Asynchronous communication mode
1: Synchronous communication mode
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01C0
16 15 14 13 12 11 10
SW01C1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01C2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01C3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01C4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01C5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01C6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
__
__
__
__
__
SW01C7
Each number in the table represents a station No.
__
Stores the synchronous/asynchronous communication operation status for each station.
0: Asynchronous
1: Synchronous
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01C8
16 15 14 13 12 11 10
SW01C9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01CA
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01CB
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01CC
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01CD
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01CE
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
__
__
__
__
__
SW01CF
Each number in the table represents a station No.
__
Appendix - 27
Description
__
__
__
120 119 118 117 116 115 114 113
is fixed to 0.
9
8
7
6
5
4
__
__
__
120 119 118 117 116 115 114 113
is fixed to 0.
9
8
7
6
5
4
__
__
__
120 119 118 117 116 115 114 113
is fixed to 0.
Appendices
3
2
1
3
2
1

Advertisement

Table of Contents
loading

Table of Contents