Download Print this page

microHAM STATION MASTER DeLuxe Manual page 39

Advertisement

Used
Defines how many relay outputs a particular unit contains. "Virtual" is a special value meaning the unit
will use zero (0) physical outputs. Virtual units are used to control virtual (conditional) switches which
effect the operation of the network but do not control physical outputs.
Slave
Specifies that outputs extend to a slave module. Only the first unit 1 (unit 1) can have a slave unit,
default value is "without extension".
Outputs
Shows the output numbers used in ascending order for the unit.
Content of this column is not editable. Outputs are assigned automatically depending on how many
relays has been defined for the unit and how many was skipped.
Assigned to
Shows to which RF box a control box or unit is assigned.
Content of this column is not editable. Assignment is done automatically according to control association
for given RF box at RF Boxes tab.
Firmware version
Displays firmware version of uLINK module when uLINK and SMD is up and running. Router check for
firmware version after configuration is loaded from the file or after click on Get versions button. Normally
is version shown in black.
IMPORTANT: When the version number is displayed in orange there is a new firmware available for this
module. When the version is red, the module using this address number does not match module type
defined in Control box column. For example, when firmware version is red for a uLINK RELAY 10 at
address=50, it means that the module with address 50 is not a uLINK RELAY 10 but some other type of
the uLINK module.
Serial number
Shows the unique serial number of the uLINK module. Serial number is required for forced firmware
update, normally not needed.
microHAM © 2016 All rights reserved
39

Advertisement

loading