Having all requirements we can start analysis.
UltraBeam and both SteppIRs have to be phased therefore they need to be connected to the Stack
Switch.
OB2-80, OB16-3 and Shunt Fed tower have a conditional use therefore they need to be connected
through virtual switch.
Inverted-V, Low Dipole and Vertical have a conditional use therefore they need also to be connected
through virtual switch.
RFS-2 must be able to supply signal simultaneously to multiple (two) R ports therefore must be
connected through N-plexer.
Rest of connections to switches can be done many ways, there is no implicit rule or guideline and every
designer will probably choose his own approach. Our example provides an optimum solution based on
antenna placement. Tower 1 is relatively close to Tower 2, TFS-4 is relatively close to RFS-2 and both
four squares are relatively close to both towers. Both beverages are far away from all other antennas as
well as Vertical and INV Vee and Low dipole. Therefore these antennas are marked as RX safe.
microHAM © 2016 All rights reserved