Virtual SW 1 is added as a "Special Box, Virtual Exclusivity Box" with 3 R ports. The switching tab is
19.
configured with the InVector 000 010 001 to support the special conditions (R ports 2 and 3 can be used
at the same time when R port 1 is not used). Since this is a virtual switch, Switching delay is set to 0.
The Control box is set to ADR: 043, Unit 2 (uLINK RELAY 10).
Virtual SW 2 is added as a "Special Box, Virtual Exclusivity Box" with 3 R ports. At switching tab is
20.
configured with the InVector 100 010 000 to support the special conditions (R ports 1 and 2 can be used
at the same time when R port 3 is not used). Since this is a virtual switch, Switching delay is set to 0.
The Control box is set to ADR: 048, Unit 2 (uLINK RELAY 10).
21.
N-Plexer added as a "Special Box, N-Plexer" with 3 R ports. The Frequency range is set individually for
each R port: R1 = 1800-2000kHz RX only, R2 = 3500-4000kHz, RX only, and R3 = 7000-7300kHz, RX
only. Switch delay is set to 0. Control box is set to address, ADR=056, Unit 4 (uLINK RELAY 6). In
addition, a "Special Box, N-Plexer, N-Plexer termination" named RFS-2' is added to provide a mirror for
the RFS-2.
22.
Stack is added as a microHAM Stack Switch. Frequency ranges are set to 7000-54000kHz for both R
ports. Include to selection is selected for both R ports to allow alternative group containing both antenna
paths for the MAIN and SUB R ports to allow Stack selection from both RX and RX2 Antenna Selections.
BOP12 (top/middle) and FULL (all three) were removed from properties and BOP23 renamed to BOP
based on the requirements to operate SteppIR 1 and SteppIR 2 out of phase. The Control box is set to
ADR: 047, Unit 1 (uLINK RELAY 10).
Double Six is added as microHAM Double Six Switch. No settings required. The Control box is set to
23.
ADR: 043, Unit 1 (uLINK RELAY 10).
Double Ten is added as microHAM Double Ten Switch. No settings required. The Control box is set to
24.
ADR: 041, Unit 1 (uLINK RELAY 10).
Once all the RF boxes have been added and configured, they can be interconnected based on the block diagram
using the Interconnections tabs of all RF boxes except the antennas as shown below.
microHAM © 2016 All rights reserved