uLINK ROTATOR: Hardware Specifications & Connectors
Power consumption:
Bus:
Outputs:
Inputs:
Dimensions:
Weight:
uLINK ROTATOR terminals description:
Top row
Description
from left
GND
Power ground, internally connected to
bottom minus and Earth terminal
S
Analog input, Rin = 10K ohm, max +/-12V
REF
+9V reference output, max. 20mA (450 ohm) +
P
Pulse input, max. 24V/5mA
CCW NC
Relay output, CCW direction, normally closed IN
CCW COM
Relay output, CCW direction, common
CCW NO
Relay output, CCW output, normally open
AUX NC
Relay output, AUX direction, normally closed
AUX COM
Relay output, AUX direction, common
AUX NO
Relay output, AUX output, normally open
CW NC
Relay output, CW direction, normally closed
CW COM
Relay output, CW direction, common
CW NO
Relay output, CW output, normally open
microHAM © 2016 All rights reserved
Power supply – max. 150mA at +13.8V (max. +15V)
Two wire differential RS-485, max. 7V at 120 ohm
3 isolated SPDT contacts CW, AUX, CCW
Contacts rating: 16A/250VAC/30VDC
Reference output 9V, max.20mA
Analog, Rin = 10kohm, max. +/- 12V
Pulse, max. 24V/5mA
W 70mm (2.7") x H 75mm (2.9") x D 110mm (4.3")
400 g (9 oz)
Bottom row
Description
from left
Earth
Grounding terminal
-
Return for power supply
Positive Power input +12-15V, max. 1.5A
G
Return for tamper input, internally
connected to minus and Earth terminal
Tamper input, max. +12V, 3mA
R
uLINK return, internally connected to R'
B
uLINK data B, internally connected to B'
A
uLINK data A, internally connected to A'
SH
uLINK CAT5 cable shield, isolated from SH'
R'
uLINK return, internally connected to R
B'
uLINK data B', internally connected to B
A'
uLINK data A', internally connected to A
SH'
uLINK CAT5 cable shield
137