Removal (Fig. 3)
1. Park machine on a level surface, lower cutting units,
stop engine, apply parking brake and remove key from
the ignition switch.
2. Raise and support hood.
3. Remove air cleaner components as needed.
Installation (Fig. 3)
IMPORTANT: Any leaks in the air filter system will
cause serious engine damage. Make sure that all air
cleaner components are in good condition and are
properly secured during assembly.
1. Assemble air cleaner components.
A. If service indicator was removed from air cleaner
housing, apply thread sealant to adapter threads be-
fore installing adapter and indicator to housing
(Fig. 5). Install adapter so that grooves in adapter
hex and adapter filter element are installed toward
service indicator. Tighten indicator from 26 to 33 in−
lb (3.0 to 3.7 N−m).
B. Orientate vacuator valve on air cleaner cover to-
ward ground.
C. Make sure that air cleaner hoses do not contact
any engine or machine components. To modify
clearance, move and/or rotate air cleaner body in air
cleaner strap. Verify that tabs in strap mesh fully with
slots in air cleaner body. Air cleaner strap should be
as close as possible to air cleaner cap. Tighten strap
screws from 16 to 19 in−lb (1.8 to 2.2 N−m).
2. Lower and secure hood.
Yanmar Diesel Engine
4
1. Air cleaner housing
2. Safety filter element
3. Air filter element
5
4
Thread
sealant
1
1. Air cleaner assembly
2. Service indicator
3. Adapter
Page 3 − 10
2
3
5
Figure 4
4. Air cleaner cap
5. Vacuator valve
Thread
sealant
2
3
26 to 33 in−lb
(3.0 to 3.7 N−m)
Figure 5
4. Groove
5. Filter element