Download Print this page

Mitsubishi Electric MELIPC MI5000 Series User Manual page 262

Hide thumbs Also See for MELIPC MI5000 Series:

Advertisement

No.
Name
SD112
Detailed information 2
information category
SD113 to
Detailed information 2
SD143
SD200
Switch status
APPX
260
Appendix 6 List of Special Registers
Content
Details
Detailed information 2
Stores detailed information 2 information category code.
information category
The following codes are stored into the information category code.
code
• 0: N/A
• 2: Drive number and file name
• 3: N/A
• 4: Parameter information
• 5: System configuration information
• 4139: Duplicate type information
Detailed information 2
Stores detailed information 2 for error code (SD0).
There are four types of information to be stored as shown in the
following figures:
• The type of detailed information 2 can be determined from SD112
"Detailed information 2 information category code". (The value of the
"Detailed information 2 information category code" stored in SD112
corresponds to (2), (4), (5) and (4139). )
■(2): Drive number and file name
SD113: With or without specification
• b0: Drive No.
• b1: File name
SD114: Drive No.
SD115 to SD122: File name (8 characters from Unicode text string
header)
■(4) Parameter information
SD113: With or without specification
• b0: Parameter type
• b1: Parameter storage destination
• b3: Parameter No.
• b4: Network No.
• b5: Station No.
• b6: System information
SD114(b0 to b7): Parameter type
• 1: Basic parameters
• 2: CC-Link IE Field Network Parameters
SD114(b8 to b15): Parameter storage location
• 4: User drive
SD115: Empty
SD116: Parameter No.
SD117: Network No.
SD118: Station No.
• 0 to 120 (0 for a master station)
■(5) System configuration information
SD113: With or without specification
• b4: CPU No.
• b5: Network No.
• b6: Station No.
SD114: Empty
SD115: Blank (If not specified, this is '0'.)
SD116(b0 to b7): Blank (If not specified, this is '0'.)
SD116(b8 to b15): CPU No. (If not specified, this is "0xFF". )
SD117: Network No. (If not specified, this is '0'.)
SD118: Station No. (If not specified, this is '0'.)
• 0 to 120 (0 for a master station)
■(4139) Duplicate type information
SD113: With or without specification
• b0: Duplicate type information
SD114: Duplicate type information
• 0: Duplication in station No.
• 5: Master/slave station duplication
Switch status (STOP/
The product switch (STOP/MAIN RUN switch) status is stored as
MAIN RUN switch)
follows.
• 0: MAIN RUN
• 1: STOP
Set by (when to
set)
S (at error
occurrence)
S (at error
occurrence)
S (at switch change)