■IP address setting
Item
IP address
settings (CH1)
*1
IP address
*1,*2
Subnet mask
Default gateway
IP address
setting (virtual
VxWorks part IP
Ethernet)
address
VxWorks part
subnet mask
*1 The IP address set value will differ depending on the subnet mask set value. Set with attention paid to the following points.
⋅ The IP address host address (subnet mask, parts that are 0) bits are not all set to 0 or 1.
⋅ The IP address network mask (subnet mask, parts that are 1) bits are not all set to 0 or 1.
*2 Set the subnet mask with attention paid to the following points.
When representing the subnet mask with a bit array (binary), 1 should not be shown again after 0.
Precautions
■IP addresses not covered in settings
The following IP address ranges cannot be set for Ethernet port (CH1).
• IP address: 172.16.0.1 to 172.31.255.255
• Subnet mask: 255.240.0.0
■Virtual Ethernet
Set the IP address of the device connected using an Ethernet port (CH1) so that it does not overlap with the virtual Ethernet
IP address segments as shown below.
• VxWorks part: 172.16.0.1
• Windows part: 172.16.0.2
• Subnet mask: 255.240.0.0
■IP address network section
Set the other device to connect and the Ethernet port IP address network to the same value.
Description
Configure the IP address, subnet mask, and default gateway of own
node CH1.
Set the own node CH1 IP address.
Configure the own node and the external device with which to
communicate to the same class and subnet address. Configure an IP
address within the range of Class A, Class B, and Class C.
Set the own node CH1 subnet mask.
This is a setting to define the top bit of the IP addresses to use for
network address that identifies the network.
For example, when assigning the top 24 bits to the subnet mask, set
255.255.255.0.
This sets the IP address of the device that pass through when
accessing the network devices outside the network where the own
node CH1 belongs to. Set the default gateway subnet address to the
same as the own station subnet address.
Configure the IP address and subnet mask of the virtual Ethernet.
Configure the VxWorks part IP address.
Configure the VxWorks part and the external device with which to
communicate to the same class and subnet address. Configure an IP
address within the range of Class A, Class B, and Class C.
Configure the subnet mask of the virtual Ethernet of the VxWorks part.
This is a setting to define the top bit of the IP addresses to use for
network address that identifies the network.
Setting range
parameter
No.
0.0.0.1 to
A012H
223.255.255.254
(Default: 192.168.3.3)
128.0.0.0 to
255.255.255.252
(Default: 255.255.255.0)
• Blank
A013H
• 0.0.0.1 to
223.255.255.254
(Default: Blank)
172.16.0.1
255.240.0.0
17 BASIC PARAMETERS