Errors detected by the CC-Link IE Field Network (Basic) (8000H to DFFFH)
This section shows the codes for errors that occurs on CC-Link IE Field Network and CC-Link IE Field Network Basic of this
product.
■Common error codes (8000H to AFFFH)
The following table shows common error codes that occur with the CC-Link IE Field Network function and CC-Link IE Field
Network Basic.
Error code
Error name
8080H
Parameter write count error
8810H
Connection fault
8811H
Basic functions error detected
8815H to 881AH
Buffer memory access error
8830H
Buffer memory access error
8845H
Buffer memory access error
8860H
Buffer memory access error
8867H
Buffer memory access error
88B0H to 88B1H
Buffer memory access error
88D0H
Slave station synchronous
communication target mismatch
88D2H
Synchronization watchdog counter
error
8900H to 890BH
Buffer memory access error
8920H to 8929H
Buffer memory access error
Description
In excess of 25 consecutive parameter
writes.
A network connection fault detected.
A basic function stop error detected.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Slave station with a mismatch between
network synchronous communication
settings in the master station network
configuration settings and network
synchronized communications settings in
the managed slave station (synchronization
Y/N) detected.
Normal communications using a CC-Link IE
Field Network synchronous slave are not
possible.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Corrective action
Do not write parameters consecutively. If an
error is generated, clear the error, turn the
power OFF to ON, or carry out a remote
RESET.
Review the wiring status.
Check the error generated by this function,
remove errors generating faults, and then
turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
• In "Network configuration settings", in
"Network Synchronous Communication
Setting", set the corresponding local
station to "synchronized".
• In local station synchronization settings
between modules, set the corresponding
module to the same settings as the
master station.
• Change the synchronization period
setting to a longer setting than the current
setting.
• Check that there are no faults with the
cable or a switching hub connections.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.