8.9
Individual Reset Function
This function resets the Windows part independently during operation of this product.
For example, use to restart the Windows part without stopping control of the VxWorks part.
Precautions
■Operations when this product is resetting
Requests of the individual reset function are ignored when this product is resetting due to a remote operation, C Controller
module dedicated function, switch operation, or other cause. Execute the individual reset function after this product resets.
■Operation during major errors and system watchdog timer errors
If a major error or system watchdog timer error is occurring on this product, requests of the individual reset function are not
executed normally. Execute this function after switching the power supply of this product OFF to ON or resetting the product to
clear errors on this product.
Windows part forced restart
Force a restart of the Windows part of this product.
Force a restart of the Windows part in the following situations.
• If a freeze or system error occurs on the Windows part
• If a system watchdog timer error occurs
The Windows part can be forced to restart for recovery without resetting this product.
A
A: VxWorks part
B: Windows part
(1) User program
(2) Restart
8 DIAGNOSTIC AND MAINTENANCE FUNCTIONS
122
8.9 Individual Reset Function
(1)
B
(1)
(2)