8.8
MELIPC Shutdown Function
This function sets the Windows part and VxWorks part to statuses in which the power can be turned OFF so that this product
can be turned OFF.
For the procedure to turn OFF the power supply of this product, refer to the following manual.
MELIPC MI5000 Series User's Manual (Startup)
Shutdown execution
Use one of the following methods to shut down this product.
■Switch operations
Use the SHUTDOWN switch.
(MELIPC MI5000 Series User's Manual (Startup))
■I/O connector
Turn on the shutdown request input for at least 1 second.
(MELIPC MI5000 Series User's Manual (Startup))
■C Controller module dedicated function
Execute the C Controller module dedicated function (CCPU_MELIPCShutdown).
• Function list
Function name
CCPU_MELIPCShutdown
For details on the C Controller module dedicated functions, refer to the following manual.
MELIPC MI5000 Series Programming Manual (VxWorks)
Operations during shutdown
The Windows part and VxWorks part enter the following statuses during a shutdown.
Target
Status
VxWorks part
The user drive write-inhibit function is executed. ( Page 104 User drive write-protected function)
Windows part
Windows is shut down. (The status in which a shutdown is executed from Windows Start. )
Advance processing during shutdown
VxWorks part processing that was registered by the user in advance can be executed before this product is shut down.
Advance processing is registered using the C Controller module dedicated function (CCPU_EntryShutdownFunc).
■Function list
Function name
CCPU_EntryShutdownFunc
For details on the C Controller module dedicated functions, refer to the following manual.
MELIPC MI5000 Series Programming Manual (VxWorks)
8 DIAGNOSTIC AND MAINTENANCE FUNCTIONS
120
8.8 MELIPC Shutdown Function
Description
Performs a shutdown operation so that the power of a MELIPC can turn OFF.
Description
Registers a routine to be called before the shutdown function of a MELIPC is executed.

Advertisement